User Tools

Site Tools


admin:poweroff

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
admin:poweroff [2023/09/08 13:50]
peppe
admin:poweroff [2024/12/17 13:11] (current)
peppe
Line 4: Line 4:
 Material may not be available during shutdown process. Material may not be available during shutdown process.
  
-Updated 08/09/2023\\+Updated 17/12/2024\\
 \\ \\
   * Altus KVM 10.1.2.10   * Altus KVM 10.1.2.10
   * Cisco switch port 6: trunk for recovery   * Cisco switch port 6: trunk for recovery
   * Backup! Transfer to safe media!   * Backup! Transfer to safe media!
 +  * Windows 7 java6 VM on 10.1.2.40 (VLAN74: 10.7.4.4, MGMT: 10.1.2.193, Internet not available)
  
 ==== Διακοπή ρεύματος ==== ==== Διακοπή ρεύματος ====
Line 17: Line 18:
   - uranus: umount /mnt   - uranus: umount /mnt
   - gaia: umount /mnt   - gaia: umount /mnt
 +
 +== Terramaster F4-424 NAS ==
 +  - Shutdown
  
 == EMC VNXe3100, 10.1.2.9 == == EMC VNXe3100, 10.1.2.9 ==
Line 50: Line 54:
 == HP DL145G2 == == HP DL145G2 ==
   - Close control units poweroff   - Close control units poweroff
-  - titan (old printserver, "shutdown -p now"), iLO 10.1.2.12\\+  - (NOT!) titan (old printserver, "shutdown -p now"), iLO 10.1.2.12\\
   - csforum, iLO 10.1.2.30\\   - csforum, iLO 10.1.2.30\\
   - aeolus, iLO 10.1.2.150\\   - aeolus, iLO 10.1.2.150\\
Line 81: Line 85:
  
 == Dell R630 #1 (UP), 10.1.2.40, iLO 10.1.2.110 == == Dell R630 #1 (UP), 10.1.2.40, iLO 10.1.2.110 ==
-  * examservers (NOT!)+  * (NOT!) examservers
  
 === Επίπεδο 2 === === Επίπεδο 2 ===
Line 108: Line 112:
   * Shutdown 10.7.4.7   * Shutdown 10.7.4.7
   * Shutdown 10.7.4.125   * Shutdown 10.7.4.125
 +  * Shutdown Windows 7 java6 VM on 10.1.2.40
   * Shutdown 10.1.2.40   * Shutdown 10.1.2.40
   * Shutdown 10.1.2.41   * Shutdown 10.1.2.41
Line 136: Line 141:
   - 1x rescue UPS   - 1x rescue UPS
  
-== EMC VNXe3100, 10.1.2.9 == +== Terramaster F4-424 NAS == 
-  Power up the system (20+ minutes! Check www!) +  Power up
-   +
-  To power up a system that is fully powered down: +
-  1. Reconnect the power cables to each DAE in the following exact order: +
-  DAE 0 +
-  DAE 1 +
-  DAE 2 +
-  Power up any remaining DAEs in ascending order. +
-   +
-  The green Power Status LED powerlines.gif on each DAE turns on. +
-  For more information on the LEDs, see System LED displays. +
-  2. Reconnect the power cables to each SP in exactly this order: +
-  SP A +
-  SP B +
-   +
-  The green Power Status LED on each SP turns on.+
  
 == HP DL380G7 esxi4, 10.7.4.125, iLO 10.1.2.104 == == HP DL380G7 esxi4, 10.7.4.125, iLO 10.1.2.104 ==
 +Add "noipmiEnabled" in boot line (Shift +o during boot), else hangs.
   - gatepc73\\   - gatepc73\\
   - gatepc74\\   - gatepc74\\
Line 161: Line 152:
  
 == HP DL145G2 == == HP DL145G2 ==
-  - titan (old printserver), iLO 10.1.2.12\\+  - (NOT!) titan (old printserver), iLO 10.1.2.12\\
   - csforum, iLO 10.1.2.30\\   - csforum, iLO 10.1.2.30\\
   - aeolus, iLO 10.1.2.150\\   - aeolus, iLO 10.1.2.150\\
Line 179: Line 170:
   * quotacheck -a   * quotacheck -a
   * quotaon -a   * quotaon -a
-  * mount /mnt 
  
 == Dell R630 #1 (UP), 10.1.2.40, iLO 10.1.2.110 == == Dell R630 #1 (UP), 10.1.2.40, iLO 10.1.2.110 ==
   * gaia   * gaia
-  * mount /mnt 
- 
  
 === Επίπεδο 3 === === Επίπεδο 3 ===
Line 191: Line 179:
   - calliope-www (cse www)\\   - calliope-www (cse www)\\
   - titan-printserver (new printserver)\\   - titan-printserver (new printserver)\\
-  - mysql-server (NOT!)\\+  - mysql-server (Only fall semester)\\
  
 == HP DL380G6 esxi3, 10.7.4.7, iLO 10.1.2.103 == == HP DL380G6 esxi3, 10.7.4.7, iLO 10.1.2.103 ==
Line 198: Line 186:
 == HP DL380G7 esxi4, 10.7.4.125, iLO 10.1.2.104 == == HP DL380G7 esxi4, 10.7.4.125, iLO 10.1.2.104 ==
   - engineering www (jupiter)\\   - engineering www (jupiter)\\
-  - charybdis (NOT!)\\+  - (NOT!) charybdis\\
  
 == Dell R630 #1 (UP), 10.1.2.40, iLO 10.1.2.110 == == Dell R630 #1 (UP), 10.1.2.40, iLO 10.1.2.110 ==
-  * examservers (NOT!)+  * (NOT!) examservers
  
 == scylla mounts == == scylla mounts ==
Line 215: Line 203:
   * Z-printer poweron   * Z-printer poweron
   * Z-printer storage poweron   * Z-printer storage poweron
 +
 +== EMC VNXe3100, 10.1.2.9 ==
 +  Power up the system (20+ minutes! Check www!)
 +  
 +  To power up a system that is fully powered down:
 +  1. Reconnect the power cables to each DAE in the following exact order:
 +  DAE 0
 +  DAE 1
 +  DAE 2
 +  Power up any remaining DAEs in ascending order.
 +  
 +  The green Power Status LED powerlines.gif on each DAE turns on.
 +  For more information on the LEDs, see System LED displays.
 +  2. Reconnect the power cables to each SP in exactly this order:
 +  SP A
 +  SP B
 +  
 +  The green Power Status LED on each SP turns on.
 +  
 +  * uranus, gaia mount /mnt
 +
  
 == Close control units == == Close control units ==