This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
admin:datacenter [2019/06/11 17:08] peppe [EMC VNXe3100 (NAS)] |
admin:datacenter [2023/03/22 10:13] (current) peppe |
||
---|---|---|---|
Line 1: | Line 1: | ||
===== Data Center ===== | ===== Data Center ===== | ||
- | ==== Rack (top to bottom) ==== | + | ==== Rack #1 (top to bottom) ==== |
{{: | {{: | ||
Line 46: | Line 46: | ||
^ Name ^ Services | ^ Name ^ Services | ||
| FIXME | | | | FIXME | | | ||
+ | |||
+ | 3x iSCSI disks for uranus: | ||
+ | Port #3 to EMC VNXe3100 SPA port #3 | ||
+ | Port #4 to EMC VNXe3100 SPB port #3 | ||
---- | ---- | ||
Line 73: | Line 77: | ||
---- | ---- | ||
- | ==== HP DL380G6 (gaia) ==== | + | ==== HP DL380G6 (ESXi #5) ==== |
{{tablelayout? | {{tablelayout? | ||
- | ^ Name | + | ^ Guests |
- | ^ Services | + | ^ OS |
- | ^ OS | FreeBSD 8.2 | | + | ^ IP | 10.1.2.205 |
- | ^ IP | 195.130.121.201 | + | ^ iLO |
- | ^ iLO | 10.1.2.105 | + | ^ Make |
- | ^ mgmt IP | 10.1.2.205 | + | ^ Model | DL380G6 |
- | ^ Make | HP | | + | ^ CPU(s) |
- | ^ Model | + | ^ RAM | 16GB | |
- | ^ CPU(s) | + | ^ Storage |
- | ^ RAM | + | ^ P/N | 491332-421 |
- | ^ Storage | + | ^ S/N | CZC9394ZBL |
- | ^ P/N | + | |
- | ^ S/N | + | |
- | 3/2018 Μηχάνημα σε αντικατάσταση προηγούμενου DL380G6 με πρόβλημα στο HDD backplane. | + | 3/2018 Μηχάνημα σε αντικατάσταση προηγούμενου DL380G6 με πρόβλημα στο HDD backplane.\\ |
+ | \\ | ||
+ | 5/2021 Αντικατάσταση μονολιθικής εγκατάστασης gaia με VM σε Dell R630\\ | ||
+ | \\ | ||
+ | 3/2023 Νέα χρήση με εγκατάσταση ESXi 5.5+webui για VMs alumni web site, dl380wsXX (XX=01-06) εικονικά μηχανήματα εργαστηρίων. Επίσης αντικατάσταση μπαταρίας cache με 4xAAA επαναφορτιζόμενες. | ||
---- | ---- | ||
Line 98: | Line 104: | ||
8GB RAM, 18x1TB NL-SAS, 3xRAID6(6-disk) groups, 3x3.7TB usable. | 8GB RAM, 18x1TB NL-SAS, 3xRAID6(6-disk) groups, 3x3.7TB usable. | ||
- | Serial console to SPA @9600 (Lazarus). | + | Serial console to SPA @9600 from Lazarus |
Restart failed management services: | Restart failed management services: | ||
Line 229: | Line 235: | ||
==== Hp Procurve 2848 J4904A Switch ==== | ==== Hp Procurve 2848 J4904A Switch ==== | ||
+ | |||
+ | IP: 10.1.2.253 | ||
{{tablelayout? | {{tablelayout? | ||
Line 288: | Line 296: | ||
==== Cisco SG200-26 Gigabit Smart Switch ==== | ==== Cisco SG200-26 Gigabit Smart Switch ==== | ||
+ | |||
+ | IP: 10.1.2.254 | ||
{{tablelayout? | {{tablelayout? | ||
Line 307: | Line 317: | ||
^ 15 | ^ 15 | ||
^ 16 | ^ 16 | ||
- | ^ 17 | + | ^ 17 |
^ 18 | ^ 18 | ||
^ 19 | ^ 19 | ||
Line 364: | Line 374: | ||
---- | ---- | ||
+ | |||
+ | ==== Rack #2 (top to bottom) ==== | ||
+ | |||
+ | === HP Procurve 2680 === | ||
+ | IP: 10.1.2.254 | ||
+ | |||
==== Out of rack ==== | ==== Out of rack ==== | ||
Line 410: | Line 426: | ||
===== Decommissioned ===== | ===== Decommissioned ===== | ||
- | ==== HP DL380G6 (old gaia) ==== | + | ==== HP DL380G6 (ESXi #4) ==== |
{{tablelayout? | {{tablelayout? | ||
- | ^ Name ^ old gaia ^ | + | ^ Name ^ ^ |
^ Services | ^ Services | ||
- | ^ OS | ESXi 5.5U3 | + | ^ OS | ESXi 5.5U3 + webui | |
^ IP | -- | | ^ IP | -- | | ||
^ iLO | 10.1.2.101 | ^ iLO | 10.1.2.101 | ||
Line 421: | Line 437: | ||
^ Model | DL380G6 | ^ Model | DL380G6 | ||
^ CPU(s) | ^ CPU(s) | ||
- | ^ RAM | + | ^ RAM |
^ Storage | ^ Storage | ||
^ P/N | 470065-082 | ^ P/N | 470065-082 | ||
Line 441: | Line 457: | ||
6/6/2019 Εγκατάσταση ESXi 5.5 και ενημέρωση σε 5.5U3 που λειτουργεί σωστά με το cache module (χωρίς μπαταρία). Επιπλέον εγκατάσταση esxui για web πρόσβαση στη διαχείριση. | 6/6/2019 Εγκατάσταση ESXi 5.5 και ενημέρωση σε 5.5U3 που λειτουργεί σωστά με το cache module (χωρίς μπαταρία). Επιπλέον εγκατάσταση esxui για web πρόσβαση στη διαχείριση. | ||
+ | |||
+ | 13/6/2019 Δίσκοι: | ||
---- | ---- |